Location Gas Day Gravity BTU CO2 % N2 % Oxygen % H2S % Methane % Ethane % Propane % I-Butane % N-Butane % Neo-Pentane % I-Pentane % N-Pentane % Hexanes % N-Heptane % N-Octane % N-Nonane %
O2 C1 C2 C3 C5 C6 C7 C8 C9
----------------------- ---------- ------- ------- ------- ------- -------- ------- --------- -------- --------- ---------- ---------- ------------- ----------- ----------- --------- ----------- ---------- ----------
BAY CHECK GC @ 170610 2025/12/24 0.5866 1.02781 1.1245 00.4871 00.0000 00.0000 94.7411 03.4468 00.1724 00.0088 00.0105 00.0000 00.0029 00.0020 00.0016 00.0012 00.0005 00.0000
CUSTER ST @ LINE AD ST1 2025/12/24 0.5854 1.02626 0.6012 01.2647 00.0000 00.0000 94.2645 03.7200 00.1435 00.0025 00.0033 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000 00.0000
GLENDALE CEGT TO MRT @ 2025/12/24 0.6004 1.05187 0.7315 00.9514 00.0000 00.0000 91.5058 06.5430 00.2433 00.0070 00.0094 00.0000 00.0019 00.0014 00.0022 00.0016 00.0008 00.0000
CHANDLER ST DISCHARGE G 2025/12/24 0.6010 1.05321 0.7099 00.9514 00.0000 00.0000 91.3798 06.6810 00.2571 00.0070 00.0079 00.0000 00.0015 00.0013 00.0012 00.0009 00.0004 00.0000
FM 63 - Columbia GC @ 2 2025/12/24 0.6047 1.07926 0.2373 00.4557 00.0000 00.0000 90.5230 08.3116 00.3785 00.0316 00.0408 00.0000 00.0084 00.0054 00.0034 00.0026 00.0012 00.0000
The information displayed above reflects daily average gas quality readings
taken at key locations on the EGT system. The dates shown above are the
dates of the readings. The readings are taken daily, and information from such
readings is posted on the first day thereafter. If on any reading day there
are problems retrieving the data, the last reported readings will remain
posted until such time as new readings are obtained. Due to factors such as
equipment failure, sample contamination and human error, the information
displayed above may not be completely accurate.